DIGITAL CALIPER INSTRUCTIONS
For more information visit www.baty.co.uk precision measuring instruments
Large Digital Workshop Caliper
Please carefully review these instructions to ensure proper and accurate use of your new Digital Caliper.
External
Measuring
Jaws
Locking screw Fine Adjustment Slider
Data OutputElectronics
Scale
Battery coverFunction buttonsInternal Measuring Jaws
Instructions:
Operating Condition: Temperature: 5 - 40º, Relative Humidity: 80%
Never apply voltage on any part of this Digital Caliper or engrave with an electro probe to avoid damaging the electronics
Prevent any liquid from contacting the protective sticker
Preset a starting point of measurement correctly (please refer to Operations). Unless presetting, do not press the 'SET' button purposely for
fear of measurement error
Functions:
ON/OFF: Press <ON/OFF> button once to turn on. Press this button again to turn off
Zero setting: Press <ZERO> function button
Change measuring mode: Press <mm/in> function button
Absolute/incremental: Press<ABS> button, to return to zero function, press this button again
Set: Presetting button
Hold: data hold button
Technical Specifications:
Resolution: 0.01mm/0.0005"
Accuracy: 0-600mm/±0.07mm
Repeatability: 0.01mm/0.0005"
Battery: 3.0V CR2032 Lithium
Battery life: Approx 1 year
Measuring speed: 3m per second
Instructions for Data Output:
Preset zero and metric/inch system
Connect the end of the interface cable to the computer, the other to the data output port of this Caliper
Start the Caliper and software
Move the slider to the position you want and press the button on control box for data output
Battery Replacement:
Once display begins flashing or even no display, slide the cover open as the arrow shows and replace with a new battery (CR 2032)
Note:
The positive pole of the battery must face out.
Please preset the starting point over again after battery replacement
Model shown: DC-60
Digital_Large_Caliper_MW150_baty 22/07/2010 13:57 Page 1
Page view 0
1 2

Summary of Contents

Page 1 - DIGITAL CALIPER INSTRUCTIONS

DIGITAL CALIPER INSTRUCTIONSFor more information visit www.baty.co.uk precision measuring instrumentsLarge Digital Workshop CaliperPlease carefully r

Page 2

Large Digital Workshop CaliperOperations:ON/OFF Button• Press ON/OFF button at any position when the power is off, this Caliper will be ready to work

Comments to this Manuals

No comments